@ Chlorine Systems .com

 

 
100 PPD Systems SO2 & Cl2
Pre-Installed on a
PVC Backing as Part
 of an Automatic Wastewater System

Neat & Clean !   -   Flexible & Serviceable !

Chlorine - Chlorine Dioxide - Sulfur-Dioxide - Ammonia

Click to Enlarge

The incoming water line, (# 1) in the center, which comes up through a True-Union Ball-Check to prevent solution falling back to our Re-Use Pump, into horizontal True-Union Ball Valves that supply both ejectors (# 2 Cl2 & # 3 SO2). System Hydraulic Pressures can be measured  @ Ports (# 7), Upstream Pressure for both Ejectors and at (# 8 & # 9) Downstream for System Diagnosis.

The Ejectors are supplied with gas through Secondary Check Valves (# 12 & # 13) for additional protection of the Flow-Proportional Valves and other equipment. If the Ejector internal checks get dirty, a high probability in Re-Use Systems at Wastewater Plants, the soft Viton Checks will seal more easily to keep water from entering the Flo-Pro's, Remote Metering Panels (# 4)  and Gas Regulators (# 10 & # 11). True-Union Ball Valves can isolate the Ejectors for quick & easy service.

Any of the True-Union Valves can have the valve body quickly replaced.

All hardware other than the Cliks hangers is 304 Stainless Steel. All PVC fittings and True Union ball valves are Schedule 80 and are made by Spears to ensure we can economically duplicate any of the pieces for repairs or replacement. Spears maintains a warehouse in Denver for wholesale to Distributors.

Our distributor is Harrington Plastics and they provide our Spears PVC piping supplies as well as other items we use for these systems.

Spare valves and fittings are always recommended so you can keep your systems running and maintain your redundancy requirements !

 

Email:      Thom@Start-UpService.com


 

500 PPD Remote Metering Panel
100 PPD Regulator System